Leak detection
Data Centres
Leak Detection for Liquid Cooling Circuits
Liquid cooling (direct-to-chip, immersion, chilled-water loops) exposes data centres to a specific risk: liquid leaks in contact with sensitive electronic equipment. CDL-Tecora develops continuous monitoring leak detection systems to secure these installations.
Key facts
- Liquid leakRisk monitored
- ContinuousMonitoring mode
Widespread liquid cooling
Direct-to-chip, immersion and chilled-water loops are spreading with the densification of computing (AI, HPC)
Continuous monitoring
Real-time detection rather than periodic rounds, for an alert from the very first moments of a leak
Linear detection under the floor
Cables or tapes laid under the raised floor or along distribution loops, able to locate a leak along a continuous length
Specifics of immersion
The dielectric fluids used in immersion are non-conductive, but their containment and monitoring remain an issue in their own right
Targeted monitoring points
Raised floor, distribution loops, connectors and at-risk fittings
Sector challenges
Business challenges
Widespread adoption of liquid cooling
The densification of computing (AI, HPC) is accelerating the adoption of liquid cooling technologies, previously reserved for niche cases, and shifting part of the process risk into the server room itself.
Late detection of a leak
A leak not detected in time can damage active equipment and cause a service interruption, with a downtime cost that far exceeds that of the equipment affected.
Many sensitive points
Raised floor, distribution loops, connectors: each data centre has its own risk map, which changes with every rack densification campaign.
Quickly locating a leak over a long length
On a raised floor of several hundred square metres, knowing that a leak exists is not enough: you also need to be able to pinpoint its approximate origin to intervene quickly and target the right aisle or rack.
Reconciling energy efficiency with risk control
The pursuit of a better PUE is driving towards more efficient liquid cooling architectures, which in turn means strengthening monitoring of the circuits so as not to turn an energy gain into an availability risk.
Distinguishing a real leak from a false positive
A detection cable under a raised floor can also react to ambient humidity or condensation near air-conditioning units, without any actual leak. A poorly set or poorly positioned system then triggers unnecessary interventions or, worse, desensitises teams to alerts.
What we offer
Our solutions for this sector
The CDL-Tecora families most used in this sector — click to see all the instruments in the family.
Regulatory framework
Applicable standards and regulations
ISO/IEC 30134-2:2016
Standard defining the calculation of PUE (Power Usage Effectiveness), the reference indicator of a data centre's energy efficiency, directly linked to the performance of the cooling system.
EN 50600-2-3
Part of the EN 50600 series of standards dedicated to environmental control of data centres, including cooling of server rooms.
FAQ
Have questions about this sector? Here are the most frequent answers.
Another question?Why is leak detection a growing topic in data centres?
Because liquid cooling (direct-to-chip, immersion, chilled-water loops) is becoming widespread with the rise of high-density computing, exposing sensitive electronic equipment to a risk of contact with liquid that did not exist, or was far lower, with air cooling alone.
Where should leak detection sensors be positioned in a data centre?
At identified risk points: under the raised floor, along the cooling liquid distribution loops, and at the most exposed connectors and fittings. The exact mapping depends on the cooling architecture chosen on the site.
What is PUE and how does it relate to cooling?
PUE (Power Usage Effectiveness) is the ratio of the total energy consumed by the data centre to that actually used by the IT equipment. Cooling accounts for a large part of this gap: it is partly to improve it that many operators are adopting liquid cooling architectures, which are more efficient than air cooling.
How does a linear leak detection cable or tape work?
Laid under the raised floor or along a distribution path, this type of detector reacts to contact with a liquid along its whole length, which makes it possible not only to signal a leak but also to indicate the approximate zone where contact occurred, rather than a simple global alarm for the room.
Does immersion cooling eliminate all risk in the event of a leak?
No. The fluid used in immersion is dielectric, that is, non-conductive of electricity, which reduces the risk of an immediate short-circuit in the event of contact with an electronic board. But this removes neither the risk of certain materials degrading on contact with the fluid, nor the need to quickly detect a leak out of the immersion tank.
What is the difference between direct-to-chip cooling and immersion?
Direct-to-chip circulates a liquid through a cold plate in direct contact with the processor, the rest of the server remaining in open air. Immersion submerges the entire server (or some of its components) in a bath of dielectric fluid. Both meet the same need to remove a high heat density, but with different architectures and leak risk points.
Can a leak detection system be integrated into the building's technical supervision?
This is the common practice: leak detection is all the more valuable when it feeds an actionable alert, in real time, to the centralised building management system (BMS) or the site's supervision system, to trigger an intervention without waiting for a periodic round.
Do traditional chilled-water loops (room air conditioning) also require leak detection?
Yes: even in a data centre that has not yet adopted direct-to-chip or immersion cooling, the chilled-water loops that feed the room air-conditioning units are hydraulic circuits, sometimes old, that can leak. Continuous monitoring is just as useful there as on a more recent liquid cooling circuit.
How can false alarms from a leak detection system in a server room be limited?
By taking into account, from the design of the system, the normal sources of ambient humidity (condensation near evaporators, humidity variations) when choosing the sensitivity and location of the detection cables or tapes, so that they react only to contact with the cooling liquid itself.
A project in this sector? Our experts are ready to help.
Personalised advice, a fast quote and technical support to choose the solution suited to your challenge.