Modern waste-to-energy plant, exterior view under a clear blue sky

Emissions monitoring

Waste-to-Energy Plants (WtE)

Waste Incineration and Energy Recovery

Waste-to-energy plants (WtE) are among the most closely monitored installations under the IED directive: continuous measurement of dust, HCl, HF, SO2, NOx, CO and TOC, and periodic or continuous monitoring of dioxins/furans and heavy metals including mercury. CDL-Tecora supplies the samplers and analysers that secure this compliance.

Key facts

  • IED Directive 2010/75/EURegulatory framework
  • 10+ parametersRegulated pollutants
  • EN 14181 QAL1-3CEMS quality assurance
A WtE plant treats waste whose composition varies from one batch to the next, which makes combustion harder to stabilise than with a homogeneous fuel. Directive 2010/75/EU (IED) and, in France, the order of 3 August 2018 on incineration plants, impose strict emission limit values and continuous monitoring (CEMS) for most regulated pollutants (dust, HCl, HF, SO2, NOx, CO, total organic compounds or TOC), supplemented by periodic campaigns, or even continuous monitoring, for dioxins, furans and heavy metals including mercury.

Multi-pollutant continuous monitoring

Dust, HCl, HF, SO2, NOx, CO, TOC continuously (EN 14181)

Dioxins and furans

Continuous sampling or periodic campaigns according to EN 1948

Mercury: continuous or sorbent trap

CVAAS spectrometry analysers for continuous monitoring, sorbent trap method as an alternative to EN 13211 manual sampling

Combustion optimisation

Better control of the air/fuel mixture reduces pollutant formation at source

CEMS quality assurance

Periodic QAL2 calibration and QAL3 monitoring to guarantee metrological reliability over time (EN 14181)

Sector challenges

Business challenges

Heterogeneous waste composition

Combustion that is harder to stabilise than with a homogeneous fuel, with an increased risk of emission peaks.

Long dioxin/furan campaigns

Reference campaigns can last several weeks and require reliable sampling without constant operator intervention.

Growing requirements on mercury

More and more prefectoral orders require continuous (CVAAS) or sorbent trap monitoring, in addition to or instead of the historical periodic manual measurements (EN 13211).

Continuous analyser failure

The regulations tolerate temporary degraded operation in the event of a CEMS failure, but any prolonged or poorly documented failure exposes the plant to the risk of an administrative shutdown of the line.

Maintaining metrological reliability over time

A poorly performed QAL2 calibration or an undetected drift between two campaigns can invalidate several months of measurements in the eyes of the inspectorate for regulated installations.

What we offer

Our solutions for this sector

The CDL-Tecora families most used in this sector — click to see all the instruments in the family.

Regulatory framework

Applicable standards and regulations

Directive 2010/75/EU (IED)

Industrial emissions, emission limit values

EN 1948

Determination of PCDD/PCDF (dioxins and furans)

EN 13284-1

Measurement of low dust concentrations

EN 14181

Quality assurance of automated measuring systems (QAL1/QAL2/QAL3)

EN 13211

Manual reference method for the determination of total mercury

EN 14385

Determination of total emissions of metals (As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V)

EN 15267

Certification of automated measuring systems (AMS) used for continuous monitoring

Order of 3 August 2018

Requirements applicable to incineration plants (France)

Frequently asked questions

FAQ

Have questions about this sector? Here are the most frequent answers.

Another question?
What is the typical duration of a dioxin sampling campaign at a WtE plant?

From a few hours to several weeks depending on the method and the objective of the campaign (one-off regulatory check or continuous monitoring over an extended period), in accordance with the protocols defined by the EN 1948 standard.

Must mercury be measured continuously at a WtE plant?

It depends on the installation's prefectoral order: more and more WtE plants are moving to continuous mercury monitoring (CVAAS analysers) or to sorbent trap sampling over several days, in addition to or in place of the historical periodic manual measurements according to EN 13211.

Why does combustion stability influence emissions?

Unstable combustion favours the formation of CO, volatile organic compounds and dioxin precursors. Better control of the air/fuel ratio reduces these peaks at source rather than treating them downstream.

What is EN 14181 quality assurance (QAL1-3)?

A set of checks staggered over time: validation at installation (QAL1), periodic calibration by comparison with the reference method (QAL2), then continuous drift monitoring (QAL3), guaranteeing the metrological reliability of the continuous analysers (CEMS) required by the IED directive.

What is the CVAAS method used to measure mercury?

Cold Vapour Atomic Absorption Spectrometry reduces the mercury sampled to elemental vapour, then quantifies it by measuring the absorption of light at the wavelength specific to mercury. A method suited to the very low concentrations found downstream of flue gas treatment.

What is mercury sampling with a sorbent trap?

A cartridge containing an adsorbent material is installed on a sampling probe and captures the mercury present in the flue gas over several days or weeks. It is then sent to a laboratory for analysis, which gives an average value representative of the period without requiring a continuous analyser or the constant presence of an operator, unlike classic one-off manual sampling.

What happens if a continuous analyser (CEMS) breaks down?

The regulations allow temporary degraded operation, for a limited period set by the installation's prefectoral order, while the operator repairs or replaces the faulty analyser. This tolerance avoids the immediate shutdown of the incineration line for the failure of a single instrument, but the incident must be logged and the analyser returned to service quickly.

What does the QAL2 calibration function actually involve?

It involves running the continuous analyser in parallel with the reference method over a series of measurements, then establishing the relationship (calibration line) between the two sets of results. This function, reassessed periodically under EN 14181, corrects any drift in the analyser and determines the validity of the measurements sent to the authorities until the next campaign.