Combustion
Glass Industry
Glass Furnaces: Flame Stability and Glass Quality
Glass melting furnaces operate continuously at very high temperatures, often for several years without a complete shutdown: the stability of the air/gas ratio directly determines the optical quality of the glass produced and the level of NOx emissions. CDL-Tecora equips the glass industry with the ADP100, a premix analyser designed specifically for this type of gas-burner furnace, whether regenerative, recuperative or oxy-combustion.
Key facts
- ADP100Historic application
- Glass BREF (IED)Sector reference document
- 5 secondsADP100 response time
Continuously operating furnace
No margin for error on air/gas ratio stability for several years
Optical quality of the glass
Directly linked to the stability of the furnace temperature and atmosphere
NOx and SO2 emissions
NOx linked to flame temperature, SO2 linked in particular to fining agents, governed by the Glass BREF (IED directive)
Regenerative cross-fired furnaces
Air/gas ratio monitoring must be carried out separately on each side of the furnace, at each flame reversal
Oxy-fuel combustion
NOx reduction technique that replaces air with pure oxygen, requiring suitably adapted dosing monitoring
Sector challenges
Business challenges
Undetected air/gas ratio drift
A slow, unmonitored drift can degrade the optical quality of the glass over several hours before being spotted visually.
NOx emissions linked to flame temperature
A furnace running too hot to compensate for poor adjustment increases NOx emissions, even if production remains visually acceptable.
Furnace with no full shutdown
The measuring instrument must be reliable over time, with no possibility of stopping the furnace for lengthy maintenance during an entire production campaign.
Separate monitoring of each side of a regenerative furnace
The periodic alternation of the flame between the two chambers means the air/gas ratio must be measured and adjusted on each side independently, with no break in monitoring during reversals.
Switching to oxy-combustion
Removing the nitrogen from the combustion air changes flame behaviour and calls for fuel/oxidant dosing control adapted to this operating mode, which differs from a conventional air/gas burner.
What we offer
Our solutions for this sector
The CDL-Tecora families most used in this sector — click to see all the instruments in the family.
Regulatory framework
Applicable standards and regulations
Directive 2010/75/EU (IED)
Industrial emissions
Glass BREF
Best available techniques for the glass sector
Directive 2003/87/EC (EU ETS)
European emissions trading system for CO2 allowances, applicable to glass melting installations above the capacity thresholds set by the directive
FAQ
Have questions about this sector? Here are the most frequent answers.
Another question?Why is the air/gas ratio so critical in a glass furnace?
The furnace operates continuously for several years: any drift in the air/gas ratio immediately affects the melting temperature and therefore the optical quality of the glass produced, while also causing the level of NOx emissions to vary.
Is the ADP100 suitable for glass fibre furnaces or only flat glass?
The ADP100 measures the air/gas ratio of any premixed industrial gas burner, whatever the type of glass furnace (flat glass, container glass, glass fibre).
What is the difference between a regenerative and a recuperative furnace?
A regenerative furnace alternates the direction of the flame between two chambers of refractory checkers that store and then release the heat of the flue gases, which improves thermal efficiency but requires the air/gas ratio to be monitored separately on each side. A recuperative furnace continuously preheats the combustion air via a heat exchanger, without flame reversal, which simplifies monitoring but generally offers lower thermal efficiency.
What is oxy-fuel combustion and how does it reduce NOx emissions?
Oxy-fuel combustion replaces all or part of the combustion air with pure oxygen. By removing atmospheric nitrogen from the reaction, it strongly limits thermal NOx formation compared with a conventional air/gas burner, where the nitrogen in the air feeds this mechanism at the high temperatures of the glass furnace.
Where do the SO2 emissions of a glass furnace come from?
SO2 comes in particular from the sulphate fining agents used in the glass composition to remove bubbles during melting, in addition to any contribution from the fuel used to heat the furnace.
Is the glass sector subject to the European carbon market?
Yes: glass melting installations exceeding the capacity thresholds set by Directive 2003/87/EC fall within the European emissions trading system (EU ETS), like other large industrial combustion installations.
Does air/gas ratio monitoring differ between flat glass, container glass and glass fibre?
The principle of air/gas ratio measurement with the ADP100 remains the same whatever the finished product. What varies mostly is the furnace technology used (regenerative or recuperative) and the combustion mode (conventional air/gas or oxy-combustion), which determine the number of measurement points and how the dosing must be adjusted.
A project in this sector? Our experts are ready to help.
Personalised advice, a fast quote and technical support to choose the solution suited to your challenge.