Our products · Environment, Hygiene and Health
Environment, Hygiene and Health

GABIE Sampling Badge for Organic Pollutants

GABIE passive badge for the simultaneous sampling of several volatile organic compounds

Need to measure the Time-Weighted Average Exposure to several organic gases at once? The GABIE badge samples by diffusion, without a pump.

The GABIE badge (Gas Adsorbent Badges for Individual Exposure) allows the simultaneous sampling of a multitude of organic gases and vapours, by diffusion onto activated carbon, in order to determine a worker's Time-Weighted Average exposure (TWA). Its reliability has been tested according to a protocol compliant with the EN 838 standard.

Simultaneous multi-gas

Samples several VOCs in a single deployment

EN 838 compliant

Reliability tested according to a rigorous protocol

Pump-free

Passive sampling by diffusion

The G.A.B.I.E. (Gas Adsorbent Badges for Individual Exposure) is a sampler that allows the simultaneous sampling of a multitude of organic gases and vapours, in order to determine a worker's Time-Weighted Average exposure (TWA).

  • Simultaneous multi-gas sampling

    Captures a multitude of organic gases and vapours in a single deployment.

  • No pump required

    Works by passive diffusion, with no sampling pump.

  • Trapping on activated carbon

    VOCs are trapped on an adsorbent medium located at the bottom of the badge.

  • EN 838-compliant reliability

    Rigorous test protocol verifying the consistency of sampling rates.

Category
Environment, Hygiene and Health
Reference
GABIE
Standards
EN 838
Country of manufacture
Made in France

Applications

Workplace hygiene

Workplace hygiene

Gas sampling

Gas sampling

FAQ

How can exposure to several organic gases be measured at the same time?+

The GABIE badge simultaneously captures a multitude of organic gases and vapours by diffusion, which makes it possible to determine a worker's Time-Weighted Average exposure in a single deployment.

Does the GABIE badge require a sampling pump?+

No, it works by passive diffusion: VOCs are captured and then trapped on activated carbon, without a pump.

How does analysis take place after sampling?+

The activated carbon is put back in a vial and sent to the laboratory, which desorbs the pollutants with a solvent and then analyses the resulting solution.

Is the reliability of the GABIE badge proven?+

Yes, it has been validated by tests following a rigorous protocol compliant with the EN 838 standard, verifying the consistency of sampling rates according to air velocity, temperature, humidity and pollutant concentration.

Got a project? Our experts are ready to help.

Personalised advice, a fast quote and technical support to choose the solution that fits your needs.