ADP200 Multi-Channel Premix Analyser
Air/gas ratio control on several combustion lines simultaneously
How can combustion be stabilised and excess energy consumption reduced when an installation has several dozen burners to control at the same time?
The ADP200 is a multi-channel premix analyser that precisely controls the air/gas ratio on a furnace or installation with up to 96 combustion lines. It stabilises burner operation, optimises thermal performance and reduces combustion drift in demanding industrial environments.
4 to 96 channels
Automated sequential control of several combustion lines
Air/gas ratio control
Accuracy on each combustion line monitored
Built-in controller
Automatic or manual selection of the channel to be controlled
Low maintenance
Quick start-up and reduced interventions
Overall energy optimisation
Reduced energy costs and combustion variations
Poorly regulated combustion on a multi-burner furnace quickly results in thermal instability, excess energy consumption, combustion drift, lower productivity and higher emissions. The ADP200 is a multi-channel premix analyser designed to precisely control the air/gas ratio of each combustion line, on installations with 4 to 96 channels.
4 to 96 channels controlled
Automated sequential control of the air/gas ratio on a large number of combustion lines from a single system.
Reduced combustion variations
Improves process regularity and reduces combustion drift across all the lines monitored.
Built-in controller
Automatic or manual selection of the channel to be controlled, for simplified supervision.
Centralised monitoring
Thermal uniformity and overall energy optimisation of the furnace or installation.
Quick start-up
Quick start-up of the analyser on the installation.
Low maintenance
Design intended to limit maintenance interventions and reduce energy costs.
Measurement principle
The sample passes through a furnace heated to 800 °C where catalytic combustion takes place; a zirconium oxide cell then measures the residual oxygen.
ISO 8573-1 instrument air
The reliability of the measurements depends on the quality of the compressed air, which must meet the purity classes of the ISO 8573-1 standard.
| Number of channels | From 4 to 96 channels |
|---|---|
| Channel selection | Automatic or manual |
| Control | Built-in controller |
| Start-up | Quick |
| Maintenance | Reduced |
| Measurement principle | Catalytic combustion at 800 °C, residual O2 measurement by zirconia cell |
| Instrument air | ISO 8573-1 compliant |
No accessory listed yet.
Applications
Glass industry
Steel Industry
Ceramics
Multi-burner furnaces
Complex thermal processes
FAQ
Got a project? Our experts are ready to help.
Personalised advice, a fast quote and technical support to choose the solution that fits your needs.