Continuous Dioxin and Furan Sampler – DECS
Continuous dioxin and furan sampler
Monitor your dioxin, furan and POP emissions continuously, without an operator.
The DECS is CDL-Tecora's solution for continuous sampling of emissions of dioxins, furans (PCDD/PCDF), PCBs and other persistent organic pollutants (POPs), compliant with EN 1948 and USEPA Method 23.
Total automation
No operator intervention required
Standards compliant
EN 1948, USEPA Method 23
MCERTS QAL1 certified
Recognised analysis quality
Remote control
Up to 100 m, Modbus communication
Up to 4 units
Centralised multi-point management
Multi-pollutant
PCBs, mercury, heavy metals, HCl
The DECS is based on the filter/condenser method with an adsorbent trap for wet gases, for sampling campaigns from 6 hours to 6 weeks. Permanently installed on the stack, its operation is fully automated: automatic isokinetic control, preparation and cleaning with no operator intervention.
100% automated operation
No operator presence required, automatic preparation and cleaning
Automatic isokinetic control
The sampling flow continuously follows the gas velocity in the duct
Up to 4 units controlled remotely
One control unit manages up to 4 sampling points, at up to 100 m
Modbus communication
Easy integration with the site's existing supervision
Adaptable to other pollutants
Configurable for PCBs, mercury, heavy metals and HCl
MCERTS QAL1 certification
Certified for gas velocities of 2 to 35 m/s.
Particulate and gaseous phases
Heated probe and filter holder, condenser, XAD-2 resin trap and Pitot tube for a representative sample.
No probe handling between campaigns
The unit stays in place; quick replacement of the filter and the XAD-2 cartridge.
Automatic traceability
Automatic temperature tracking, leak tests, volume calculation, alarm log and sampling report.
| Sampling duration | 6 hours to 6 weeks |
|---|---|
| Sampling units controlled | Up to 4 |
| Control unit / sampling unit distance | Up to 100 m |
| Communication | Modbus |
| Electrical supply | 220 V AC – 50 Hz – 16 A |
| Instrument air | 6 bar, clean and oil-free |
| Certified velocity range (MCERTS) | 2 à 35 m/s |
| Materials | Glass, titanium |
| Sampling method | Filter/condenser, XAD-2 adsorbent trap (wet gases) |
| Measurable pollutants | PCDD/PCDF, PCBs (adaptable to Hg, heavy metals, HCl) |
| Mounting | DN150 port (DN100 on request) |
| Screen / interface | 10" LCD, keyboard, Modbus connection |
| Dimensions (sampling unit) | 540 x 804 x 360 mm (L x H x P) |
| Weight (sampling unit) | 37 kg |
| Dimensions (control unit) | 600 x 1800 x 600 mm (L x H x P) |
| Weight (control unit) | < 130 kg |
| Control unit | Colour screen, data logger, automatic start on process signal |
Applications
Waste incineration plants
Biomass power plants
Thermal power plants
Cement works
Energy recovery installations
Chemical industries
Sites subject to regulatory POP monitoring