Our products · Laboratory
Laboratory

Laboratory Fume Cupboard

NF XP X 15-206 Compliant Laboratory Fume Cupboard

Secure the handling of your chemicals with a fume cupboard that detects containment failures.

This laboratory fume cupboard complies with the NF XP X 15-206 standard in force and combines air inlet velocity monitoring, a visual and audible alarm, and a secure sash to protect the operator during handling.

Containment failure alarm

Air inlet velocity monitoring with visual and audible alert

NF XP X 15-206 compliant

Standard in force for laboratory fume cupboards

Secure 400 mm opening

Manually releasable lock

Position switch (option)

Flow regulation according to opening height

Low-energy lighting

Two electronic fluorescent tubes

Standard

NF XP X 15-206

Transom thickness

6 mm

Opening height

400 mm

Lighting

2 low-energy fluorescent tubes

A laboratory fume cupboard must above all prevent operator exposure in the event of a containment failure. This model continuously monitors the air inlet velocity and triggers a visual and audible alarm as soon as a failure is detected; some versions can also be fitted with a position switch, which regulates the airflow according to the sash opening height.

  • Containment failure detection

    Permanent air inlet velocity monitoring, with visual and audible alarm.

  • Position switch control

    Automatically adapts the flow rate to the sash opening height (equipped versions).

  • Opening limited to 400 mm

    Locking system that can be manually released for wider access.

  • 6 mm Sécurit glass transom

    Front protection by 6 mm thick toughened glass.

  • Low-energy lighting

    Two low-energy electronic fluorescent tubes.

Category
Laboratory
Reference
XP X 15-206 Fume Cupboard
Standards
NF XPX 15-206

Applications

Chemistry and analysis laboratories

Chemistry and analysis laboratories

Handling of volatile chemicals

Handling of volatile chemicals

FAQ

How does this fume cupboard signal a containment failure?+

It permanently monitors the air inlet velocity and triggers a visual and audible alarm as soon as a containment anomaly is detected.

Does this fume cupboard comply with French regulations?+

Yes, it complies with the NF XP X 15-206 standard in force for laboratory fume cupboards.

Can the sash be opened higher than 400 mm if needed?+

The opening is limited to 400 mm by a locking system, but this can be manually released for wider access.

Does the airflow adapt to the sash opening?+

On versions fitted with a position switch, yes: flow regulation automatically follows the opening height.

Got a project? Our experts are ready to help.

Personalised advice, a fast quote and technical support to choose the solution that fits your needs.